Gage R&R calculator (average and range method)
Enter the study layout, the average range across all appraisers, the difference between the highest and lowest appraiser averages, and the tolerance. The calculator uses the AIAG average and range method to return repeatability (EV), reproducibility (AV), combined gauge R&R, %GRR against the tolerance and, given the range of part averages, against total variation with the number of distinct categories.
Measurement system
- %GRR of tolerance
- -
- %GRR of total variation
- -
- Repeatability, EV
- -
- Reproducibility, AV
- -
- Gauge R&R, GRR
- -
- Part variation, PV
- -
- Distinct categories, ndc
- -
EV, AV, GRR and PV are standard deviations in the units you measured in.
The formulas
EV = R̄̄ × K1
AV = √[ (X̄diff × K2)² − EV² / (n r) ]
GRR = √(EV² + AV²) PV = Rp × K3 TV = √(GRR² + PV²)
%GRR of tolerance = 100 × 6 GRR / tolerance
%GRR of TV = 100 × GRR / TV ndc = 1.41 × PV / GRR, rounded down
Here n is the number of parts and r the number of trials. K1 depends on the trials (0.8862 for 2, 0.5908 for 3), K2 on the appraisers (0.7071 for 2, 0.5231 for 3), and K3 on the parts, as in the table below. These are the constants from the AIAG Measurement Systems Analysis manual, fourth edition, where every result is a standard deviation. Against the tolerance, the gauge's spread is taken as 6 of those standard deviations.
Worked example
Ten parts, three appraisers, three trials each. The average range is 0.35, the appraiser averages differ by at most 0.5, the tolerance is 5 and the part averages span 3.2.
- EV = 0.35 × 0.5908 = 0.2068.
- AV = √[(0.5 × 0.5231)² − 0.2068² / 30] = 0.2588.
- GRR = √(0.2068² + 0.2588²) = 0.3313.
- %GRR of tolerance = 100 × 6 × 0.3313 / 5 = 39.8%.
- PV = 3.2 × 0.3146 = 1.0067, so %GRR of total variation is 31.3% and ndc is 4.
Both percentages are over 30%, and ndc is under 5. This gauge cannot be trusted to sort these parts, and reproducibility is the larger share, so the first place to look is how the appraisers hold, fixture or read it.
K3 by number of parts
| Parts | K3 |
|---|---|
| 2 | 0.7071 |
| 3 | 0.5231 |
| 4 | 0.4467 |
| 5 | 0.4030 |
| 6 | 0.3742 |
| 7 | 0.3534 |
| 8 | 0.3375 |
| 9 | 0.3249 |
| 10 | 0.3146 |
Questions
What %GRR is acceptable?
The usual guidance from the AIAG Measurement Systems Analysis manual: under 10% is acceptable, 10% to 30% may be acceptable depending on the importance of the measurement, the cost of the gauge and the risk, and over 30% needs improvement. Many customers also want the number of distinct categories to be 5 or more.
Should I compare GRR to the tolerance or to the total variation?
Compare to the tolerance when the gauge is used to sort good parts from bad. Compare to total variation when the gauge is used to control or improve the process, because there it has to see differences between parts, not just between pass and fail.
Why does the appraiser variation subtract a term?
The difference between appraiser averages also contains some repeatability error, because each average comes from a finite number of trials. Subtracting EV squared over parts times trials removes that share. If the result goes negative, the appraiser variation is taken as zero.
Revision 24 Nov 2026: %GRR of tolerance now uses six standard deviations, as the AIAG manual does. Earlier versions divided one standard deviation by the tolerance, which understated it six-fold. Part variation, total variation and ndc were added.
Next frame Yours